HomeAbout UsProductNewsProjectContactChinese
Self Priming Pump ListWFJ Sealless Self control Self priming PumpZX Self-priming PumpZD Self-priming Sewage Pump
ZD Self-priming Sewage Pump
ZD Self-priming Sewage Pump is designed for delivering large solid particles and long fiber impurities, with advantages of simple structure, good self-priming performance, high sewage capacity, high efficiency, energy saving, convenient usage and maintenance, It is widely used in municipal sewage project, river and pond breeding, light industry, paper making, weaving, foodstuff, chemical industry, power industry, fibrin, chemical medium, slurries and mixed suspension etc.
ZD Self-priming Sewage Pump is applicable to urban environmental protection, construction, fire protection, chemical industry, pharmacy, dye,printing and dyeing, brewing, electric power, ferry, paper making,industrial and mining washing, equipment cooling, etc.
  • Technical Parameter
  • Other Description

Structure Drawing of Type Sproull® ZD Pump

1 Coupling   components 7 Bearing seat 13 Self-priming   pump body 19 Self-priming   pump cover 25 Front bearing
2 Coupling key 8 Stoma cover 14 Self-priming impeller 20 O-ring 26 Oil mark
3 Dust Cover 9 Circlip 15 PTFE mat 21 Impeller key 27 Rear bearing gland
4 Small Round Nut 10 Axles 16 O-ring 22 Water pipe joint 28 Suspension bracket
5 Stop washer 11 Water pipe joint 17 Pump body 23 Front bearing gland
6 Rear bearing 12 Mechanical Seal 18 Impeller 24 Baffle ring

Sproull® ZD Preformance Curve

lllustrations of Model Type
ZD80-50-200
ZD Self-priming Centrifugal pump
80 Refer to pump suction diameter(mm)
50 Refer to pump dischange diameter(mm)
200 Refer to impeller nominal diameter(mm)

Sproull® ZD Preformance parameter list

Type Speed
n(r/min)
Capacity
Q(m³/h)
Head
H(m)
Eff
η(%)
Shaft power
pa(kw)
Motor power
(kw)
NPSHr
(m)
50-32-250 2900 12.5 80 33 8.25 15 2.0
65-40-250 2900 23.3 69 46 9.52 15 2.5
80-50-200 2900 50 50 63 10.8 15 2.5
100-65-200 2900 100 50 72 18.9 30 3.9
125-100-315 2900 200 125 70 97.2 160 5.2
150-125-400 1450 200 50 70 38.9 55 3.5
200-150-400 1450 400 50 78 69.8 90 3.5
Only part of the product model demonstration
If the actual requirements of performance parameters and performance table does not match, can be based on user requirements for design and manufacture.

Sproull® ZD Installation Drawing(Demonstration)

Type Installation Dimensions(mm)
L1 L2 L3 L4 L5 L6 L7 L8 H1 H2 H3 Inlet flange Outlet flange
a1 a2 a3 a4 a5 a6 m-Φ1 b1 b2 b3 b4 b5 b6 n-Φ1
ZD80-50-200 1185 100 60 100 820 1020 445 505 476 160 276 200 160 132 80 20 3 8-Φ17.5 165 125 99 50 20 3 4-Φ17.5
Working Condition:
Capacity: 2-650m³/h
Head: 3.5-150m
Working pressure:<1.6Mpa
Working Temperature:-50 – +200℃
Materials:304,316L,2507 Stainless steel,Steel Lining Teflon.

Design features:

• The pump is with self-priming performance, It don’t need any bottom valve.
•  Electric motor and diesel engine driven for options.
• The total weight of impurities in the medium can not exceed 15% of the total media weight.
• Medium specific weight not more than 1240kg/m³.
• The unique structure of open impeller makes sure the free pass of solids in sewage with max size of 60% of outlet DN and fiber 150% of impeller diameter.
• The self priming sewage pump is widely applicable for the lines of urban diacharge projects, light industry, papermaking, textile, foodstuff, chemicals, electric power, petroleum, mines, aquiculture and so on.

Previous
Return
86-510-85627001
sales@wxspring.com
123 Gaoyun Road, Binhu District, Wuxi City
Wuxi Spring Hydro Equipment CO., Ltd